INICIO > Blog > Cátodo común vs. ánodo común: Alimentación LED para exteriores

Cátodo común vs. ánodo común: Alimentación LED para exteriores

Use configuration-specific maximum power to check supply requirements and a defined operating average to estimate energy use. Common cathode can reduce drive losses; whether it is the better purchase depends on the complete build, required brightness and running schedule.

Gabinete LED estándar cuadrado 960 para exteriores, visto desde el frente y la parte posterior.
Standard Square 960. Power figures must match the selected pitch, brightness and build.

What changes with common cathode and common anode?

In a common-anode RGB LED, the colour channels share a positive connection; in a common-cathode RGB LED, they share a negative connection. The power-supply and driver design determine how those LEDs are operated.

Typical architecture, not a Square wiring diagram
Arquitectura de interiores Acuerdo de suministro típico Qué verificar
ánodo común tradicional A shared supply rail serves RGB channels with different forward-voltage needs. LEDs, driver losses, supply efficiency and the complete configuration’s power rating.
Common cathode with split supplies Red can use a lower supply voltage than green and blue, reducing excess voltage across the drive path. The actual supply and driver arrangement, plus power at the required delivered brightness.

Texas Instruments’ application report explains these approaches and alternative supply arrangements. A common-cathode design can reduce drive losses, but its name alone does not establish a saving percentage. Compare the complete display, including LEDs, drivers, power supplies and operating settings.

Maximum power, average power and energy use

Use each number for its intended decision
Figura Usalo para Check before using it
Maximum power, W/m² Calculating the screen load as an input to electrical design. Exact configuration, brightness, rating conditions and included equipment.
Catalogue average, W/m² An initial operating-budget reference. The basis of the average; it is not a guaranteed reading for your content.
Measured operating average, W/m² Estimating consumption for a defined playback and brightness schedule. Measurement duration, content, settings, environment and meter location.
Energy, kWh Calculating consumption over time and applying the relevant electricity tariff. Daytime, evening, standby and auxiliary-equipment consumption.

A maximum catalogue rating should not automatically be described as a full-white test result. Ask which conditions it represents. Supply planning also needs the relevant input-current, startup, protection and installation requirements; an average-power estimate cannot replace those checks.

How to compare two outdoor LED power specifications

For an “under 500 W/m²” requirement, first define whether 500 is the maximum or average, the required delivered brightness and the equipment included. A 170 W/m² average cannot demonstrate compliance with a 500 W/m² maximum.

  • Salida de la pantalla: same area and pitch, brightness after white balance and calibration, and white point.
  • Reproducción: same test pattern or content sequence, brightness schedule, refresh and scan settings.
  • Medición: same input conditions, ambient conditions, stabilization period, duration and AC measurement boundary.
  • Build: record the LEDs, driver ICs, supplies and cabinet version being compared.

Separate catalogue ratings from measurements. Record whether receiving cards and control equipment are included, and account for external heaters or cooling. The sum of power-supply DC output ratings is not a measurement of the screen’s AC input power.

Different-brightness catalogue rows can help shortlist configurations, but their difference is not a same-condition efficiency result. Common-cathode selection also requires compatible modules, drivers and power supplies; confirm the build rather than assuming an IC replacement is sufficient.

Standard Square or Pro for a power-limited project?

Comience con Cuadrado estándar 960 if its dimensions, IP65 protection and selected power specification fit the project. Its confirmed current 10,000-nit build uses common anode; common cathode is also available by order. Each option needs its own power specification.

Match the configuration to the project
Requisitos del proyecto Ruta de configuración
Standard dimensions and protection fit; the selected power rating meets the budget. Choose standard Square 960 and confirm the order specification.
Standard cabinet fits, but a common-cathode build is requested. Assess the standard model’s common-cathode option with configuration-specific brightness and power values.
Common cathode as standard, front-and-rear IP66 or Pro’s six cabinet sizes are needed. Assess Square 960 Pro, checking the chosen pitch against the power limit.

Square 960 Pro lists maximum power of 450 W/m² for P4/P4.44/P5 and 390 W/m² for P5.71/P6.67/P8/P10. These catalogue values make it a candidate for a maximum below 500 W/m²; confirm the required brightness and rating conditions in the quote. High brightness or low-temperature requirements alone do not determine which version to choose.

If the project needs a 1000 mm cabinet grid or different pitch, compare the outdoor display range. Square 1000 Pro lists 550 W/m² maximum for P2.97/P3.91/P4.81 and 390 W/m² for P6.25/P7.81/P10.42. The below-500 claim therefore applies only to the relevant configurations.

When do operating savings justify the configuration cost?

Use a comparable operating average for each option, the expected schedule and the actual quoted price difference. Longer runtimes and higher electricity rates increase the value of a verified energy reduction; they do not establish the reduction themselves.

Where annual savings are positive and supported, simple payback is the additional purchase cost divided by annual operating-cost savings. Use measured or clearly identified estimated inputs with the same scope. Do not derive a payback period from differently configured catalogue rows or assume that a 50% brightness setting means 50% power.

What to confirm in the power specification

  1. The exact model, pitch, cabinet layout, drive architecture and component configuration.
  2. Delivered brightness and the maximum power rating for that configuration.
  3. The basis of any average-power figure: content, schedule, measurement conditions and included equipment.
  4. The site’s available power and the electrical requirements to check before installation.

A short requirement such as “maximum below 500 W/m²” or “10 kW available for the screen” is enough to start a configuration discussion. Include the required brightness or pitch if already decided.

Preguntas Frecuentes
Does common cathode always use less power than common anode?
Common cathode can reduce drive losses through an appropriate supply and driver design, but the label does not establish a fixed whole-screen saving. Compare configurations at the same delivered brightness, pitch and operating conditions. LED efficiency, driver settings and power supplies also affect the result. Ask for the configuration details and the basis of each power figure before comparing savings.
Which power figure should I use to plan the electrical supply?
Use the selected configuration’s maximum power rating as an input to electrical design, together with its input-current and startup requirements, auxiliary loads and installation conditions. Average power is for operating estimates and cannot establish the required supply capacity. Confirm the relevant electrical documentation for the actual screen; a per-square-metre rating alone does not specify circuit protection or cable sizes.
Is the catalogue average the power my screen will actually use?
Treat a catalogue average as a planning reference. Your operating average depends on content, brightness settings, the daily schedule and the equipment included in the measurement. Ask how the figure was established, then use a representative measurement or clearly identified estimate for the project. Include external control, heating or cooling loads where they are outside the screen’s stated power figure.
What does a requirement below 500 W/m² need to specify?
State whether the limit applies to maximum or average power, the required delivered brightness, the exact model and pitch, and the measurement boundary. A low average does not prove compliance with a maximum limit. Check each configuration: Square 960 Pro lists maximum ratings of 450 or 390 W/m², while Square 1000 Pro’s three finer pitches list 550 W/m².
Do I need Square Pro to choose common cathode?
Standard Square 960 can be configured for common cathode by order. Square 960 Pro uses common cathode as standard and offers front-and-rear IP66 protection and six cabinet sizes. Choose the version around the complete project requirements. Confirm brightness and power for the selected build; the standard model’s regular catalogue figures should not be assumed to apply to an optional build.
Can I compare power figures at different brightness levels?
You can use them to identify candidate configurations, but they do not establish a same-condition energy saving. For that comparison, match delivered brightness after calibration, pitch, white point, playback and measurement conditions. Record hardware differences and included equipment. Compare maximum ratings separately from operating averages, and use the same operating schedule when estimating energy consumption or a payback period.

Analice sus requisitos de brillo.

Cuéntenos qué funciones necesita la pantalla. Podemos sugerirle una configuración cuadrada y confirmar los detalles de brillo y potencia para su presupuesto.

Solicitar cotización
Sigue leyendo
Tráenos el resumen

Comienza tu proyecto.

Un dibujo, una foto del lugar o una idea inicial. Cuéntanos qué tienes planeado y trabajaremos en los detalles con nuestro equipo de ingeniería.

Utilizamos estos datos para responder a su proyecto. Aviso de privacidad.